Ludlums - About Robert Ludlum’s The Bourne Shadow. When secrets from Bourne’s past come to light, he may be the next thing that’s buried in this latest entry in the legendary New York Times bestselling series. It’s been over a decade since Nash Rollins recruited a brilliant, talented, but disaffected young man named David Webb to join Treadstone.

 
LudlumsLudlums - This device may be mounted to the Model 177-Series of benchtop counters to provide protection against unintended modifications to the instrument's alarm setting. It is constructed of aluminum and has two drilled holes for screw-mounting it to the instrument. 7328-021. Description. Part Number.

The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, networkability, battery backup, and various options such as remote indicators, printers, relays, and more. Includes Check Source and Holder. The 14C-RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the robust and versatile Model 14C Survey Meter, which houses an internal energy compensated GM ...Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the …Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672 The Model HBP-29 is a whole-body contamination monitor designed to measure personnel leaving controlled areas. Standard features include: 29 beta plastic detectors with semiconductor readout. Stainless steel housing for easy cleaning and durability. Ergonomic detector positioning. Hand-detector on the side. Integrated 17 in. touch-screen display. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. Includes Adjustable Shoulder Strap. The Model 30-7 Series are handheld, lightweight neutron dose detectors that join the Model 30 digital meter with a 19.5 cm (7.7 in) diameter REM ball containing a 3 He detector. The instruments use similar detectors that only differ by the boron concentration in the internal borated layer.Ludlum Measurements Inc, Sweetwater, Texas. 490 likes · 1 talking about this · 801 were here. Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection instruments and techIncludes up to 12 gas proportional or scintillation detectors for surveying large areas mounted on a roll-around cart. Configurations: Model 240 Gas Proportional Floor and Wall Monitor. Model 240S Scintillation Floor and Wall Monitor. Model 240-1 Gas Proportional Floor Monitor. Model 240S-1 Scintillation Floor Monitor. 48-3956.Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the … The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area. Allows HV measurement and pulse injection into any Model 26 family of instruments (excluding the Model 26S) from 2019 and later. 99 cm (39 in.) long, C to test pin. 8303-1044. Display #. The Model 26-1 is a variant of the Model 26 with an additional units button to display measurements in terms of cps, cpm, mR/hr, µSv/h, dpm, or Bq. Shipping Address. All instruments requiring service should be shipped to the following address: Ludlum Measurements, Inc. Attn: Service Department. 501 Oak Street. Sweetwater, TX 79556. USA.The Model 3-97 provides a great solution for locating potential contamination and then accurately measuring the exposure rate, or for simply measuring the ambient exposure levels over a wide range. The … Ludlum Measurements, Inc - The parent company, operating since 1962. A designer and manufacturer of radiation detection instrumentation and equipment used to monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Tel: (325) 235-5494. Toll Free: (800) 622-0828 (US and Canada ... Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech SupportIndicated Use. Tritium surface survey / Windowless beta survey. Designed to be placed on a flat surface and then purged with P-10 gas for 20 seconds before counting. Detector Type. Gas flow proportional. Window. Windowless. Window Area. Active: 126 cm 2 (19.5 in 2)User-Selectable Internal and External Detectors. Ludlum's Model 3-98 is uniquely configured to optimize measurements for 125 I and any alpha, beta, or gamma contamination. The dual detector design allows the user to select the detector for the task at hand. The internally-housed GM pancake detector can be used to measure gamma.Rad Pro Calculator is a useful online tool used to perform calculations in radiation and radiological industries, such as health physics, radiochemistry, radiation physics, and radiological engineering. Calculators include unit conversions (SI and US customary), dose rate and activity, and isotope decay. A free downloadable application for ...The cable-less Model 26 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard 15.51 cm 2 GM pancake probe, loud audio “click” output, and …Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the …Robert Ludlum was the author of twenty-seven novels, each one a New York Times bestseller. There are more than 210 million of his books in print, and they have been translated into thirty-two languages. He is the author of The Scarlatti Inheritance, The Chancellor Manuscript, and the Jason Bourne series--The Bourne Identity, The Bourne ...Rad Pro Calculator is a useful online tool used to perform calculations in radiation and radiological industries, such as health physics, radiochemistry, radiation physics, and radiological engineering. Calculators include unit conversions (SI and US customary), dose rate and activity, and isotope decay. A free downloadable application for ...Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech Support Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum. Model 44-110. Windowless Gas Flow Proportional. For Tritium/Beta Detection. 126 cm 2 (19.5 in 2) 3 H : 25%. Windowless Gas Flow Proportional Detector. Active Window Area: 126 cm 2 (19.5 in 2) 3 H Efficiency: 25%. Display #.The Model 375P-1000 is a digital Model 375 Controller coupled to two shielded 7866 cm 3 (480 in 3) plastic scintillator detectors. The detectors are encased in weathertight enclosures suitable for the outdoor environment. The Model 375 Controller is not weatherproof and must be mounted either indoors or within an environmental enclosure ...The Model 43-2-2 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 9.7 cm 2 (1.5 in 2 ) active window area.2 days ago · Serial Number Reading Units Cumulative Dose Cumulative Start Cumulative Reset Site Building Area Location Status Alarm Message Received IP Address; 237025: 3.00 External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select …Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech Support The cable-less Model 26-2 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard GM pancake detector and large auto-ranging LCD display into one convenient package, making it easier than ever to detect contamination. Operation is simplified through the use of just two buttons. Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh …Indoor/Outdoor Use. Model 375-30. Two 7.6 x 2.5 cm (3 x 1 in.) (Dia x L) NaI (Tl) Scintillator Detectors. Lead Shielding. Indoor/Outdoor Use. Model 375P-336 Series. Two 2753 cm 3 (168 in 3) Plastic Scintillator Detectors. Range: 0 to 9999 kcps. Indoor or Outdoor Use Depending on Model.Order of Robert Ludlum Books. Robert Ludlum (1927-2001) was an American author who has written dozens of thrillers. He is perhaps best known for his Bourne Trilogy novels, which were made into movies starring Matt Damon. Ludlum started writing in the ’70s. During that time, he was living in Leonia, New Jersey and spent hours every day writing.The Model 3078 Series Stretch Scopes are designed to survey areas for gamma radiation while maintaining distance from potentially high radiation fields. These instruments include external GM detectors mounted at the end of a 4.7 m (15.3 ft.) carbon fiber telescoping pole, allowing the detector to reach areas difficult to access with other types ...Alternative to Ludlum Models 18 and 2221. The Model 3003 is a durable, lightweight instrument designed for alpha, beta, gamma, or neutron radiation survey. It can support up to four external detectors, each with its own set of calibration and user parameters. The Model 3003i is a version that includes an internal GM or scintillation detector.Find your region's Ludlum representative or dealer. US Contacts. International Contacts. OR. Contact Ludlum Sales: (800) 622-0828 (USA Toll Free) (325) 235-5494. Subscribe to our customer newsletter! Stay informed about Ludlum products and … This device may be mounted to the Model 177-Series of benchtop counters to provide protection against unintended modifications to the instrument's alarm setting. It is constructed of aluminum and has two drilled holes for screw-mounting it to the instrument. 7328-021. Description. Part Number. The Model 44-94 is a pancake GM detector for measuring alpha, beta, and gamma radiation. It has a 62 cm 2 (9.6 in 2 ) active window area.The Model 375P-1000 is a digital Model 375 Controller coupled to two shielded 7866 cm 3 (480 in 3) plastic scintillator detectors. The detectors are encased in weathertight enclosures suitable for the outdoor environment. The Model 375 Controller is not weatherproof and must be mounted either indoors or within an environmental enclosure ... Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the Model 1. This instrument eventually evolved into the Model 3 Survey Meter and is still one of LMI’s best-selling instruments. The company opened its first facility at ... These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. This device may be mounted to the Model 177-Series of benchtop counters to provide protection against unintended modifications to the instrument's alarm setting. It is constructed of aluminum and has two drilled holes for screw-mounting it to the instrument. 7328-021. Description. Part Number.Alternative to Ludlum Models 18 and 2221. The Model 3003 is a durable, lightweight instrument designed for alpha, beta, gamma, or neutron radiation survey. It can support up to four external detectors, each with its own set of calibration and user parameters. The Model 3003i is a version that includes an internal GM or scintillation detector.Ludlum Measurements offers both Alpha-Beta Gas Proportional and Gamma Scintillator Detectors for use in surveying pipes and tubing. All detectors listed here include an eye on one or both ends to attach a pull rope or cable. Click on the model number to view the product drawing or main product page. Product. Description. Part Number. Model 43-94.4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, analog ratemeter known for accuracy and long-lasting dependability. It comes in a variety of measurement ranges and units to support the external radiation detector selected.Product Manuals. This section presents current product manuals for most of our instruments. They can also be found on the respective product pages under the Documents tab. Please check the serial number on your instrument to ensure it falls within the range of the serial numbers listed on the manual on this website.The Model 3078 Series Stretch Scopes are designed to survey areas for gamma radiation while maintaining distance from potentially high radiation fields. These instruments include external GM detectors mounted at the end of a 4.7 m (15.3 ft.) carbon fiber telescoping pole, allowing the detector to reach areas difficult to access with other types ...The Ludlum Model 30-4 joins the Model 30 digital display unit with a 22.9 cm (9 in.) REM ball containing a 3 He detector, thereby providing a significant weight reduction and more compact, maneuverable instrument for determining neutron dose rates.Three modes of operation – RATE, MAX, and COUNT – are available for the user.Ludlum Measurements, Inc. (LMI) designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum, we offer a large array of …The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area.Features. The Model 5 is a gamma exposure ratemeter equipped with two internally housed, energy-compensated GM detectors that measure over the range of 0 to 20 mSv/h (0 to 2000 mR/hr). The cast aluminum instrument housing with its separate battery compartment and accompanying metal handle offer an industrial robustness and quality that promote ...When an Ludlum Model 3 survey meter is ordered with a Model 44-9 pancake GM detector and the customer requests a dual scale mR/hr and cpm meter face, we would send a 202-608 meter face. However, if the customer ordered at Model 44-6, sidewall GM detector, we would send a 202-241. A list of meter scales and compatible detectors are listed on the ... The Model 44-3 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 5 cm 2 (0.8 in 2 ) active window area. Product Manuals. This section presents current product manuals for most of our instruments. They can also be found on the respective product pages under the Documents tab. Please check the serial number on your instrument to ensure it falls within the range of the serial numbers listed on the manual on this website.The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason Bourne was an unforgettable agent in the top-secret CIA Black Ops program, Operation Treadstone. Now, author Joshua Hood has created a new protégé, Adam Hayes.The Model 43-2 is a ZnS(Ag) scintillator detector for measuring alpha radiation. It has a 9.6 cm 2 (1.5 in 2 ) active window area.Network and Relay Options. 48-Hour Battery Backup. CE Certified. The Model 375 is a versatile, compact, and easy-to-use digital electronic controller designed for monitoring radiation in areas. Its simple design accommodates many different detectors to suit a wide variety of applications, and it is equipped with a local readout and alarms.Model 44-110. Windowless Gas Flow Proportional. For Tritium/Beta Detection. 126 cm 2 (19.5 in 2) 3 H : 25%. Windowless Gas Flow Proportional Detector. Active Window Area: 126 cm 2 (19.5 in 2) 3 H Efficiency: 25%. Display #.Ludlum Measurements, Inc. | 813 followers on LinkedIn. Committed to making the world a safer place to live and work by providing affordable, dependable, and durable equipment. | Ludlum ...Hardcover – July 25, 2023. Someone's killing Treadstone agents and Jason Bourne may be next on the list in this latest electrifying entry in Robert Ludlum’s #1 New York Times bestselling series. From the glacial waters of Alaska to a sexy nightclub in the Bahamas, Treadstone agents are being hunted down and murdered.Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool.Model 375 Webpage & Service Software. Collects and displays radiation levels and alarm status from up to 50 Model 375 instruments. The Model 375 must be equipped with Ethernet interface. Using this interface, the area monitor can be connected to the network allowing for real-time monitoring of radiation data, email alerts, and database logging.Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672Bourne are a series of three novels by Robert Ludlum based on the fictional spy Jason Bourne.The series has since been further extended by Eric Van Lustbader after the …Dead-Time Correction (DTC) Allows Gamma Measurements Up to 1999 µSv/h (1000 mR/hr) The Ludlum Model 26-3 incorporates electronics and a time-tested GM detector in an ergonomically designed, ruggedly-constructed, and water-resistant housing. The integrated instrument is cable-less thereby simplifying the process of frisking people and objects.Features. The Model 5 is a gamma exposure ratemeter equipped with two internally housed, energy-compensated GM detectors that measure over the range of 0 to 20 mSv/h (0 to 2000 mR/hr). The cast aluminum instrument housing with its separate battery compartment and accompanying metal handle offer an industrial robustness and quality that promote ...Part Number: 48-1677. The Ludlum Model 500 Pulse Generator provides the functions necessary for use in calibrating Ludlum radiation detection instruments as well as many other scaler/ratemeter instruments from other manufacturers. The adjustable output pulse rate is displayed on a three-digit LED readout. Potentiometers (both coarse and fine ... The Model 44-7 is an end window GM detector for measuring alpha, beta, and gamma radiation. It has a 6 cm 2 (0.93 in 2 ) active window area. The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ...4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, analog ratemeter known for accuracy and long-lasting dependability. It comes in a variety of measurement ranges and units to support the external radiation detector selected. Ludlum Measurements offers the option to retrofit existing portal monitor systems with the electronics and software used in our Model 4525 Series, including systems manufactured by our competitors. Retrofitting allows you to upgrade an aging system without having to purchase new detector housings and stands. Besides our own systems, Ludlum has ... About Robert Ludlum’s The Bourne Shadow. When secrets from Bourne’s past come to light, he may be the next thing that’s buried in this latest entry in the legendary New York Times bestselling series. It’s been over a decade since Nash Rollins recruited a brilliant, talented, but disaffected young man named David Webb to join Treadstone.Features. Integrated, Lightweight Ergonomic Design. High-Impact Plastic with Water-Resistant Rubber Seals. Employs Standard 15.51 cm 2 GM Pancake Detector. Displays in mR/hr, µSv/h, dpm, Bq, cpm, or cps. Dead-Time Correction (DTC) Allows Gamma Measurements Up to 500 mR/hr or Up to 1999 µSv/h. Simple Three-Button Operation.Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech SupportThe Ludlum Model 23 mrem Electronic Personal Dosimeter (EPD) is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is ...Includes up to 12 gas proportional or scintillation detectors for surveying large areas mounted on a roll-around cart. Configurations: Model 240 Gas Proportional Floor and Wall Monitor. Model 240S Scintillation Floor and Wall Monitor. Model 240-1 Gas Proportional Floor Monitor. Model 240S-1 Scintillation Floor Monitor. 48-3956.Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website.Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website.Ludlum Measurements, Inc - The parent company, operating since 1962. A designer and manufacturer of radiation detection instrumentation and equipment used to monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Tel: (325) 235-5494. Toll Free: (800) 622-0828 (US and …Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool. Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ... Model 43-44-1 Alpha Detector - Ludlum Measurements Inc. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information. (800) 622-0828 (US, CA) (325) 235-5494. (325) 235-4672. After Hours Tech Support. For 375P & 4525 Series: (800) 717-9506. To search products by model number ...Examples of his novels include the following: The Scarlatti Inheritance The Matlock Paper The Rhinemann Exchange The Holcroft Covenant The Bourne Identity The Bourne Supremacy The Bourne Ultimatum The Apocalypse Watch The Sigma Protocol. Among the most popular books by Robert Ludlum is the Bourne series.Features. The Model 9DP is a digital, hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Measurements and instrument status are displayed on a large, 232K-color, backlit LCD screen.4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, …Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh local produce”!Louis a weiss memorial hospital, Cascade hospital for animals, Prince lebanese grill, Sheraton music city, Perry family practice, Refresh dental, King arthur baking company, Black veil brides tour, Regal north brunswick, Fortworth isd, Grinnell mutual reinsurance company, Martin county property appraiser, Luzerne county pennsylvania, Bassett mirror company

Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection …. Wood carvers near me

Ludlumsmurr from impractical jokers

Allows HV measurement and pulse injection into any Model 26 family of instruments (excluding the Model 26S) from 2019 and later. 99 cm (39 in.) long, C to test pin. 8303-1044. Display #. The Model 26-1 is a variant of the Model 26 with an additional units button to display measurements in terms of cps, cpm, mR/hr, µSv/h, dpm, or Bq. The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason … The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence. Shipping Address. All instruments requiring service should be shipped to the following address: Ludlum Measurements, Inc. Attn: Service Department. 501 Oak Street. Sweetwater, TX 79556. USA. Find your region's Ludlum representative or dealer. US Contacts. International Contacts. OR. Contact Ludlum Sales: (800) 622-0828 (USA Toll Free) (325) 235-5494. Subscribe to our customer newsletter! Stay informed about Ludlum products and …User-Selectable Internal and External Detectors. Ludlum's Model 3-98 is uniquely configured to optimize measurements for 125 I and any alpha, beta, or gamma contamination. The dual detector design allows the user to select the detector for the task at hand. The internally-housed GM pancake detector can be used to measure gamma.Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ... Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the Model 1. This instrument eventually evolved into the Model 3 Survey Meter and is still one of LMI’s best-selling instruments. The company opened its first facility at ... Temperature dependent. Drop Resistance. Survives 100g drops in three orientations. Size (H x W x L) 25.7 x 10.8 x 10.8 cm (10.125 x 4.25 x 4.25 in.) Weight. 2.2 kg (5 lb) Note: For gamma backgrounds greater than 100 mR/h, we recommend using Model 42-31H. Model.Alpha-Beta Gas Proportional Detector. The Models 43-37 and 43-37-1 are large-area gas proportional detectors for alpha and beta survey. Originally designed to be used with the Model 239-1 Floor Monitor, both detectors are compatible with a number of counting instruments. P-10 (10% methane, 90% argon).The cable-less Model 26-2 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard GM pancake detector and large auto-ranging LCD display into one convenient package, making it easier than ever to detect contamination. Operation is simplified through the use of just two buttons.The Ludlum Model 3000 is a durable, lightweight instrument that is used with an external detector for alpha, beta, and gamma radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic, and splash-resistant construction ... The Model 44-17 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 17.8 cm 2 (2.8 in 2 ) active window area. Height Above Floor Easily Adjusted. Rate, Max, and Count Modes. The Model 3002/FM Series Alpha-Beta Floor Monitors allow a user to quickly survey large areas for alpha-beta contamination. They combine the dependable Model 3002 Alpha-Beta Survey Meter with two alpha-beta scintillation detectors in configurations ideal for floor monitoring.The Model 3078 Series Stretch Scopes are designed to survey areas for gamma radiation while maintaining distance from potentially high radiation fields. These instruments include external GM detectors mounted at the end of a 4.7 m (15.3 ft.) carbon fiber telescoping pole, allowing the detector to reach areas difficult to access with other types ...These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25 Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. Sample holder for max. 5.1 x 1.5 cm (2 x 0.6 in.) [D x L] samples. 47-3865. Model 43-93. High Temperature Version. This version has a plastic scintillator designed for use at higher temperatures, up to 50 °C (122 °F). …About Robert Ludlum’s The Bourne Shadow. When secrets from Bourne’s past come to light, he may be the next thing that’s buried in this latest entry in the legendary New York Times bestselling series. It’s been over a decade since Nash Rollins recruited a brilliant, talented, but disaffected young man named David Webb to join Treadstone.Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment.The world’s most ruthlessly efficient assassin, Jason Bourne, is facing the one force he can’t defeat—his own past—in the latest thrilling entry in Robert Ludlum’s New York Times bestselling series. Three years ago, Jason Bourne embarked on a mission in Estonia with his partner and lover, a fiery Treadstone agent code-named Nova. Their job was to … Shipping Address. All instruments requiring service should be shipped to the following address: Ludlum Measurements, Inc. Attn: Service Department. 501 Oak Street. Sweetwater, TX 79556. USA. Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool. Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum. Ludlum Measurements, Inc. | 813 followers on LinkedIn. Committed to making the world a safer place to live and work by providing affordable, dependable, and durable equipment. | Ludlum ... Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and material monitoring ... The Model 44-40 Series are shielded GM (Geiger-Mueller) detectors capable of detecting alpha, beta, or gamma radiation. Both the Model 44-40 and 44-40-2 have lead shielding. The Model 44-40 has a painted lead … Shipping Address. All instruments requiring service should be shipped to the following address: Ludlum Measurements, Inc. Attn: Service Department. 501 Oak Street. Sweetwater, TX 79556. USA. The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS (Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. This combined system supplies independent backlit LCD readouts to support discriminated alpha and beta sample counting. The Ludlum Model 30-4 joins the Model 30 digital display unit with a 22.9 cm (9 in.) REM ball containing a 3 He detector, thereby providing a significant weight reduction and more compact, maneuverable instrument for determining neutron dose rates.Three modes of operation – RATE, MAX, and COUNT – are available for the user.Indoor/Outdoor Use. Model 375-30. Two 7.6 x 2.5 cm (3 x 1 in.) (Dia x L) NaI (Tl) Scintillator Detectors. Lead Shielding. Indoor/Outdoor Use. Model 375P-336 Series. Two 2753 cm 3 (168 in 3) Plastic Scintillator Detectors. Range: 0 to 9999 kcps. Indoor or Outdoor Use Depending on Model.Hardcover – July 25, 2023. Someone's killing Treadstone agents and Jason Bourne may be next on the list in this latest electrifying entry in Robert Ludlum’s #1 New York Times bestselling series. From the glacial waters of Alaska to a sexy nightclub in the Bahamas, Treadstone agents are being hunted down and murdered.Features. This intrinsically safe general purpose ratemeter is patterned after Ludlum's best-selling Model 3. It was designed and tested to USA standards for intrinsic safety, permitting it to be used in potentially explosive atmospheres. The Model 3-IS can only be used with select detectors to sustain the intrinsic safety rating.The Model 3001-3RK (formerly called Model 3001-3RK2) consists of several dependable, high-quality detectors matched with the versatile Model 3001 survey meter. The devices are packaged in a rugged transport and …Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh …These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and …Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ...The Ludlum Model 30 is a versatile and lightweight display unit intended for use with with an external detector for alpha, beta, or gamma radiation survey. Three modes of operation – RATE, MAX, and COUNT – are available for the user. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes in cps, Bq ...Includes Check Source and Holder. The 14C-RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the robust and versatile Model 14C Survey Meter, which houses an internal energy compensated GM ...Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech SupportThe 2241-2RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the digital, auto-ranging, and versatile Model 2241-2 Scaler-Ratemeter that can measure exposure, contamination, and samples. Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website. Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool.Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ...Features. The Model 9DP-1 is a digital, hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. This meter is specially designed for radiography work where pulsed fields are being measured.The Model 52 Portal Monitor is used for Beta-Gamma personnel contamination monitoring and meets the FEMA standard for Emergency Response Portal Monitoring (FEMA-REP-21). It is designed to be assembled in five minutes or less without tools, and can be quickly disassembled for ease of transportation and storage. This gamma/neutron survey meter combines Ludlum Model 2363 survey meter with the Model 42-41L PRESCILA neutron detector. The gamma detector is an energy compensated GM housed internally to the survey meter. The neutron detector is a proton recoil type, which provides excellent measurement results at less weight than the more traditional REM balls. The Model 52-1, 52-5, and 52-6 Series Portable Portal Monitors are used for beta-gamma contamination monitoring on personnel and meet the FEMA standard for Emergency Response Portal Monitoring (FEMA-REP-21). They are designed to be disassembled for ease of transportation and storage, and can be set up in five minutes or less without any …When contacting us through email, please remember to fill in the "Subject" line so that we can quickly assess your needs. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Office Hours: 8:00 am - 5:00 pm CST, Monday - Friday. Toll Free: 800-622-0828 (US & Canada) Tel: 325-235-5494. Fax: 325-235-4672.The Model 375-20 is a Digital Model 375 Controller coupled to two shielded 5.1 cm (2 in.) diameter by 5.1 cm (2 in.) thick NaI (Tl) scintillation detectors. The detectors are encased in weathertight enclosures suitable for the outdoor environment, but the Model 375 Controller is normally mounted to a wall indoors near an operator.The Ludlum Model 3000 is a durable, lightweight instrument that is used with an external detector for alpha, beta, and gamma radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic, and splash-resistant construction ...Robert Ludlum bibliography. Robert Ludlum (1927–2001) was an American author of twenty-seven novels between 1971 and 2006, the last being issued five years after his death. [1] Of his twenty-seven novels, two were originally published under the pseudonym of Jonathan Ryder and another under the pseudonym of Michael Shepherd.To reduce costs without compromising performance, the 375P-3500 system also utilizes Ludlum's highly popular Model 375 type controller that controls the detector, updates background, and carefully monitors the passing scrap metal. The controller can operate totally independently, or be wired for remote annunciation, or connected to an Ethernet ... Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672 Order of Robert Ludlum Books. Robert Ludlum (1927-2001) was an American author who has written dozens of thrillers. He is perhaps best known for his Bourne Trilogy novels, which were made into movies starring Matt Damon. Ludlum started writing in the ’70s. During that time, he was living in Leonia, New Jersey and spent hours every day writing.Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment.. E j auction, Options behavioral health, Beignoisette, Running group near me, Blaze credit union, Samhsa mental health, Natural way lawn, Salem friends of felines, Chesrown.